특징 및 규격 |
Hamilton은 산업 전반에 걸쳐 사용되는 다양한 종류의 표준주사기와 주문제작주사기를
공급하고 있습니다. 다양한 구조로 된 0.5 μL ~ 2 L 범위의 용량을 가진 주사기 최고 수준의 정밀도와 정확도를 제공합니다. 800 여종의
주사기는 주사기형태와 용량, 터미널 구조, 주사기니들의 굵기, 길이 , 형태에 따라 800 여종의 주사기가
있습니다. |
Syringe Terminations; Terminations are
located at the end of the syringe barrel and function as the interface between
the syringe and its mating connection such as the needle. Terminations are
offered in a number of different needle and connection configurations to
accommodate a broad range of applications.
N, Cemented Needle
|
SN, Special Cemented Needle
|
LTN, Luer Tip Cemented Needle
|
LTSN, Luer Tip Cemented Needle Special
|
LT, Luer Tip
|
RN, Removable Needle
|
KH, Knurled Hub
|
FN, Fixed
Needle
|
TLL, Teflon Luer Lock
|
BFP, Bubble
Free Prime
|
SL, SampleLock™
|
C, ChemSeal
|
CA, Carbon
Analyzer
|
DX, Diluter with Stop
|
DAD, Diluter AccuDil
|
AD, AccuDil
|
Tracheal
|
|
|
Point Style; Several different needle point
styles are offered on Hamilton syringe and needle products depending on the
application. The correct point style varies depending on the intended
application. Below are a few examples of common applications.
Point Style 2 |
Point Style 3 |
Point Style 3T |
Point Style 4 |
Point Style 5 |
Point Style
AS |
|
Gauge Index ; When selecting
a needle gauge it is important to keep in mind the volume of the syringe and the
dead volume of the needle. For example, it will be very difficult to prime a 10
µL syringe if the dead volume in the needle is greater than 10 µL. Refer to the
gauge index to choose a needle gauge with an appropriate µL/inch before
selecting a needle. Select the minimum length that allows you to carry out your
application comfortably.
Gauge |
Nominal OD(mm) |
Nominal ID(mm) |
Wal Thickness(mm) |
Volume(uL/inch) |
34 |
0.159 |
0.051 |
0.051 |
0.052 |
33 |
0.210 |
0.108 |
0.051 |
0.233 |
32 |
0.235 |
0.108 |
0.064 |
0.233 |
31 |
0.261 |
0.133 |
0.064 |
0.353 |
30 |
0.312 |
0.159 |
0.076 |
0.504 |
29 |
0.337 |
0.184 |
0.076 |
0.675 |
28 |
0.362 |
0.184 |
0.089 |
0.675 |
27 |
0.413 |
0.210 |
0.102 |
0.876 |
26s |
0.474 |
0.127 |
0.178 |
0.322 |
26 |
0.464 |
0.260 |
0.102 |
1.349 |
25s |
0.515 |
0.153 |
0.178 |
0.464 |
25 |
0.515 |
0.260 |
0.127 |
1.349 |
24 |
0.566 |
0.311 |
0.127 |
1.930 |
23s |
0.642 |
0.116 |
0.267 |
0.268 |
23 |
0.642 |
0.337 |
0.152 |
2.266 |
22s |
0.718 |
0.168 |
0.279 |
0.563 |
22 |
0.718 |
0.413 |
0.152 |
3.403 |
21 |
0.819 |
0.514 |
0.152 |
5.271 |
20 |
0.908 |
0.603 |
0.152 |
7.255 |
19 |
1.067 |
0.686 |
0.191 |
9.389 |
18 |
1.270 |
0.838 |
0.216 |
14.011 |
17 |
1.473 |
1.067 |
0.203 |
22.715 |
16 |
1.651 |
1.194 |
0.229 |
28.444 |
15 |
1.829 |
1.372 |
0.229 |
37.529 |
14 |
2.109 |
1.600 |
0.254 |
51.076 |
13 |
2.413 |
1.804 |
0.305 |
64.895 |
12 |
2.769 |
2.159 |
0.305 |
93.000 |
11 |
3.048 |
2.388 |
0.330 |
113.728 |
10 |
3.404 |
2.693 |
0.356 |
144.641 | | |
주문정보 |
Microliter Syringes; Microliter syringes are for use with liquids only. They
incorporate a hand-fitted stainless steel plunger with a finely bored syringe
barrel. These syringes are ideal for homogeneous samples that are not prone to
precipitation or bonding with glass. Under the proper conditions, plunger wear is minimal and
the life of a Microliter syringe is almost unlimited. However, when using
heterogeneous solutions with a Microliter syringe, the user must be especially
diligent about cleaning the syringe after each use. For more information, see
our Hamilton Syringe Care and Use Guide on properly maintaining our
syringes. In some cases, even
diligent cleaning is not sufficient and the barrel will become soiled. The
deposits on the glass will compromise the tight tolerances between the glass and
the plunger resulting in a frozen plunger. Plungers for Microliter syringes
cannot be interchanged or replaced if damaged. For heterogeneous solutions, a
Gastight syringe is the best option.
|
Gastight Syringes; Gastight syringes are ideal for
dispensing both liquids and gases. They have a precision-machined PTFE plunger
tip which creates a leak-free seal. With the tight fit, the tip essentially
wipes the interior of the syringe barrel free of sample. This feature is
particularly useful with heterogeneous samples as it reduces the chance that a
deposit will occur and cause the plunger to freeze.
|
Calibrated Syringes; Hamilton Company offers a calibration service for precision
syringes and Digital Syringes. A Certificate of Calibration is provided with the
product and the procedure is performed with an unbroken chain of calibrations
traceable to N.I.S.T.
Calibrated precision syringes are available only at the time of purchase. To
order a calibrated syringe, add the prefix "CAL" to the beginning of the
syringe's part number. For example, to order a calibrated 701N, 10 μL syringe
(part number 80300), request part number CAL80300. |
Digital Syringes ; Reading
graduations is always a challenge. The Hamilton Digital Syringe eliminates
parallax errors by providing a digital readout on its integrated LCD screen. An
adjustable plunger-stop guarantees reproducible plunger placement. Easily
achieve precision up to 0.5% while dispensing volumes from 500 µL down to 50
nL. |
Carbon Analyzer Syringes; These
syringes are for water analysis with Total Organic Carbon (TOC) analyzers. The
wetted parts are stainless steel and borosilicate glass. The plungers and
barrels are not interchangeable or replaceable. |
Chromatography & Analytic Syringes; Hamilton
Company manufactures a complete range of syringes for partial loop filling,
complete loop filling and reverse loop filling by the aspiration HPLC technique.
Syringes for a complete range of GC applications, including: capillary and
packed column methods, on-column and split/splitless injection techniques, use
of Merlin Microseal™ and JADE injectors and headspace sampling protocols. Find
the ideal syringe for High Performance Liquid Chromatography (HPLC), Gas
Chromatography (GC) or Thin Layer Chromatography (TLC) by selecting the
applicable sub category or see a list of all chromatography syringes by
selecting the filtering tool.
|
Instrument Syringes; For over 50 years Hamilton has been
the trusted partner for robotic and clinical diagnostic instrumentation. Our
syringes provide the accuracy and precision that enables many of the automated
processes around the laboratory. In addition to syringes for Hamilton equipment
we offer a wide variety of syringes for other automated systems.
|
Life Science Syringes; Hamilton Company offers a wide
variety of specialized syringes for life science applications. From custom
needles to specialized animal injections and gel loading syringes Hamilton has a
solution for your precision liquid handling application.
|
Needles; Hamilton Company offers the widest variety of
standard and custom needles in the industry. Manufactured from 304 stainless
steel and with needle gauges from 10 to 34 and lengths from 0.375 to 12+ inches
almost any needle is possible.
|
Syringe Accessories; Hamilton manufactures a variety of
syringe accessories to improve or modify the functionality of a standard
syringe. There are solutions that prevent plunger bending and increase
reproducibility to cleaning tools that prolong the life of a syringe.
| |
귀하의 성공적인 연구개발의 동반자가 되겠습니다.
******************************************************************************************************************* (주)동방하이테크상사 http://www.allpump.co.kr 서울시 성동구 광나루로6길 35 성수이비즈센터 710호 T)02-457-6292 F)457-6293 dbht@allpump.co.kr ******************************************************************************************************************* 정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
|