LONGER
LSP 주입식 정밀 주사기펌프[LSP Infusion Syringe Pumps]
by DBHT
2019. 12. 17.
| | | LSP 주입식 정밀 주사기펌프 |
| [LSP Infusion Syringe Pumps] |
| | |
|
|
|
|
|
|
|
|
규 격 | + 확대한 그림보기-> | LSP01-1A
| LSP01-2A
| LSP02-2A
| LSP04-1A
| Working Mode | Infusion | Channel | 1 | 2 | 4 | Syringe | 10 uL ~ 60 mL | 10 uL ~ 10 mL | Stroke | 140 mm | Pusher Advance | 0.156 um/step | 0.03125 um/step | 0.156 um/step | Linear Speed | 5um/min~65 mm/min | 1 um/min ~ 13 mm/min | 5um/min~65mm/min | Linear Resolution | 5 um/min | 1 um/min | 5 um/min | Linear Accuracy | ≤±0.5% when ≥30% of pump stroke | Linear Force | ≥9 kg (20 lbs) | ≥29 kg (64 lbs) | ≥18 kg (40 lbs) | Syringe Selection | Built-in syringe branched, size and inner diameters | Syringe Defined | Can store four user-defined syringe inner diamerters | Flowrate Calibration | Improve flowrate accuracy | Running Parameter | Infusion volume, infusion time, etc | Display Setting | Display volume, flowrate or linear speed | Power-off Memory | Storing the running parameters automatically | State Output | OC gate signal to indicate start/stop and direction | Control Input | Falling edge or TTL signal to control Start/Stop | Communication | RS-485 | Diemensin | 280 L x 210 W x 140 mmH | 280x250x140 mm | Weight | 3.6 kg | 4.5 kg | Power | AC 90-260V/15W | AC 90-260V/20W |
| Syringe | Diameter (mm) | LSP01-1A (uL/min~mL/min) | LSP01-2A (uL/min~mL/min) | LSP02-2A (uL/min~mL/min) | LSP04-1A (uL/min~mL/min) | 10 uL | 0.50 | 0.001-0.0128 | 0.0002-0.0026 | 0.0002-0.0026 | 0.001-0.0255 | 25 uL | 0.80 | 0.0025-0.0327 | 0.0005-0.0065 | 0.0005-0.0065 | 0.0025-0.0653 | 50 uL | 1.10 | 0.0048-0.0618 | 0.0095-0.0124 | 0.0095-0.0124 | 0.0048-0.1235 | 100 uL | 1.60 | 0.0101-0.1307 | 0.002-0.026 | 0.002-0.026 | 0.0101-0.2614 | 250 uL | 2.30 | 0.0208-0.2701 | 0.0042-0.054 | 0.0042-0.054 | 0.0208-0.5401 | 500 uL | 3.25 | 0.0415-0.5392 | 0.0083-0.1078 | 0.0083-0.1078 | 0.0415-1.0784 | 1.0 mL | 4.72 | 0.0875-1.1373 | 0.0175-0.2275 | 0.0175-0.2275 | 0.0875-2.2747 | 2.0 mL | 9.00 | 0.3181-4.1351 | 0.0636-0.827 | 0.0636-0.827 | 0.3181-8.2702 | 5.0 mL | 13.10 | 0.6739-8.7608 | 0.1348-1.7522 | 0.1348-1.7522 | 0.6739-17.522 | 10 mL | 16.60 | 1.0821-14.068 | 0.2164-2.8135 | 0.2164-2.8135 | 1.0821-28.135 | 20 mL | 19.00 | 1.4176-18.429 | 0.2835-3.6859 | 0.2835-3.6859 | - | 30 mL | 23.00 | 2.0774-27.006 | 0.4155-5.4012 | 0.4155-5.4012 | - | 60 mL | 29.14 | 3.3346-43.349 | 0.6669-8.6699 | 0.6669-8.6699 | - |
|
|
|
주문정보 | Model | Product code | Channel | Pusher Advance | Linear Force | LSP01-1A | 050340A | 1 | 0.156 um/step | ≥9 kg (20 lbs) | LSP01-2A | 050341A | 1 | 0.03125 um/step | ≥9 kg (20 lbs) | LSP02-2A | 050347A | 2 | 0.03125 um/step | ≥29 kg (64 lbs) | LSP04-1A | 050345A | 4 | 0.156 um/step | ≥18 kg (40 lbs) |
|
|
|
기술자료 | LSP01(04)-1A Syringe Pump Calibration (Release Time:2017-01-06) The flowrate can be calibrated for more accurate dispense volume. 1. In parameters setting interface, press and turn RES to highlight the Calibration line. Press RES to enter calibration interface. 2. Testing time line is highlighted. Press RES to highlight the numerical value position. Turn RES to select the testing time. The testing time is from 0.5 minutes to 60 hours. Press RES to confirm. 3. Press Run/Pause key to start the testing. After testing, turn RES to highlight the testing volume line. Press RES to highlight the numerical value position. Enter the actual volume from the membrane keypad. Press RES to confirm. 4. After calibration, the linear speed of the Pusher Block changes to increase the accuracy of the dispense volume. | LSP01(04)-1A Syringe Pump Power Up (Release Time:2017-01-06) This option is only applicable when no dispense volume is selected. When power returns after an interruption the pump can resume operation (select Run) or remain stopped (select Stop). | LSP01(04)-1A Single Channel Syringe Pump Flowrate setting (Release Time:2017-01-06) In parameters setting interface, turn and press RES to highlight the flowrate setting line. Press RES to make the numerical value position highlighted. Enter the flowrate required from the membrane keypad. Press RES to set flowrate unit. Turn RES to scroll through the list and press RES to select the unit required. Possible flowrate units are µl /h, µl/m, ml/h, ml/m. The highlighted display indicates that this parameter can be changed. Note: If the number entered exceeds the maximum flowrate possible then the pump prompts the maximum feasible flowrate at the Time position. To continue enter a flowrate smaller than the maximum. | LSP01(04)-1A Single Channel Syringe Pump Volume setting (Release Time:2017-01-06) In parameters setting interface, turn and press RES to highlight the volume setting line. Press RES to make the numerical value position highlighted. Enter targeted volume from the membrane keypad. Press RES to set volume unit. Turn RES to scroll through the list and press RES to select the unit required. Possible volume units are µl and ml, i.e. microliter and milliliter. The highlighted display indicates that this parameter can be changed. Note: When the volume setting is zero, the LCD will display the flowrate setting and the pump will run until manually stopped or a stall occurs. |
|
|
|
|
|
귀하의 성공적인 연구개발의 동반자가 되겠습니다. ******************************************************************************************************************* (주)동방하이테크상사 http://www.allpump.co.kr 서울시 성동구 광나루로6길 35 성수이비즈센터 710호 T)02-457-6292 F)457-6293 dbht@allpump.co.kr ******************************************************************************************************************* 정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
|
가성비와 가심비가 내려가는 Longer Pump(롱거펌프)를 소개합니다.
#액체이송펌프, #액체토출펌프, #자흡식펌프